Part Details | CIRCUIT BREAKER BOX
5925-00-244-7418 An enclosure which includes, mounts, and protects one or more circuit breakers. It is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. May include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. May include handle tie bars. It is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. For boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see SWITCH BOX; JACK BOX; TERMINAL BOX; and DISTRIBUTION BOX. For boxes designed to mount and protect but do not include circuit breakers, see CIRCUIT BREAKER BOX SUBASSEMBLY. See also INTERCONNECTING CABINET; PANEL, POWER DISTRIBUTION; JUNCTION BOX; and CABINET, ELECTRICAL EQUIPMENT.
Alternate Parts: WEQ48, WEQ4-8, WEQ4, W0408ML1125, 5925-00-244-7418, 00-244-7418, 5925002447418, 002447418
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) | 
|---|---|---|---|
| 59 | JUN 09, 1973 | 00-244-7418 | 19365 ( CIRCUIT BREAKER BOX ) | 
REFERENCE DRAWINGS & PICTURES
4 POINT-RECTANGULAR
 
							RECTANGULAR, SURFACE MOUNTING
 
					Cross Reference | NSN 5925-00-244-7418
| Part Number | Cage Code | Manufacturer | 
|---|---|---|
| WEQ4-8 | 30086 | SPD ELECTRICAL SYSTEMS, INC | 
| WEQ4 | 30086 | SPD ELECTRICAL SYSTEMS, INC | 
| W0408ML1125 | 30086 | SPD ELECTRICAL SYSTEMS, INC | 
Technical Data | NSN 5925-00-244-7418
| Characteristic | Specifications | 
|---|---|
| STYLE DESIGNATOR | RECTANGULAR, SURFACE MOUNTING | 
| OVERALL DEPTH | 4.125 INCHES NOMINAL | 
| OVERALL HEIGHT | 12.250 INCHES NOMINAL | 
| OVERALL WIDTH | 6.500 INCHES NOMINAL | 
| MATERIAL | STEEL | 
| SURFACE TREATMENT | PAINT | 
| MOUNTING METHOD | UNTHREADED HOLE | 
| STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR | 
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.500 INCHES NOMINAL | 
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 10.250 INCHES NOMINAL | 
| SYSTEM FOR WHICH DESIGNED | THREE WIRE SINGLE PHASE | 
| MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 100.0 | 
| MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | B120.0$$B240.0 | 
| CIRCUIT BREAKER TYPE AND QUANTITY | 8 SINGLE POLE AND 8 DOUBLE POLE | 
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | RAINTIGHT-NEMA TYPE 3R |