Part Details | THERMOSTATIC SWITCH
5930-00-028-4314 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: A19AGA24, A19AGA24C, A19AGA-24C, 5930-00-028-4314, 00-028-4314, 5930000284314, 000284314
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | OCT 17, 1972 | 00-028-4314 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-028-4314
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| A19AGA24 | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
| A19AGA-24C | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
Technical Data | NSN 5930-00-028-4314
| Characteristic | Specifications |
|---|---|
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | -30.00 TO +50.00 ACTUATION POINT DEGREES FAHRENHEIT AND -30.00 TO +50.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT POINTER WITH SCALE AND EXTERNAL ACTUATION POINT POINTER WITH SCALE |
| CONTACT STIMULUS RATING | AF10.00 ACTUATION POINT NOMINAL AND AF5.00 DEACTUATION POINT NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| CAPILLARY TUBE LENGTH | 84.0 INCHES NOMINAL |
| BULB LENGTH | 2.500 INCHES NOMINAL |
| BULB DIAMETER | 0.366 INCHES NOMINAL |