Part Details | PRESSURE SWITCH
5930-00-045-9921 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: NA5820001C, NA5-82000-1C, 1001000, 100-1000, 98000, 5U5021, 5930-00-045-9921, 00-045-9921, 5930000459921, 000459921
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-045-9921 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-045-9921
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| NA5-82000-1C | 43999 | BOEING COMPANY, THEDBA BOEING |
| 100-1000 | 19696 | NOVA-NETICS CORP |
| 98000 | 81873 | WOODWARD HRT, INC. |
| 5U5021 | 60029 | WOODWARD, INC.DBA WOODWARD HRT |
Technical Data | NSN 5930-00-045-9921
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 6 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 6.112 INCHES NOMINAL |
| OVERALL HEIGHT | 3.562 INCHES MAXIMUM |
| OVERALL WIDTH | 1.500 INCHES NOMINAL |
| BODY LENGTH | 5.000 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BB1500.00 ACTUATION POINT NOMINAL AND BB1000.00 DEACTUATION POINT NOMINAL AND BB500.00 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | THREADED STUD |
| MOUNTING METHOD | BASE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.275 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.500 INCHES NOMINAL |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.500 INCHES NOMINAL |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.750 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.375 INCHES NOMINAL |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |