Part Details | THERMOSTATIC SWITCH
5930-00-050-9525 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: MEG88026, 17300, 5930-00-050-9525, 00-050-9525, 5930000509525, 000509525
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1961 | 00-050-9525 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-050-9525
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MEG88026 | 10855 | CARRIER CORPORATION |
| 17300 | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
Technical Data | NSN 5930-00-050-9525
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 1 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 4.922 INCHES NOMINAL |
| BODY DIAMETER | 0.625 INCHES NOMINAL |
| BODY LENGTH | 3.594 INCHES NOMINAL |
| OVERALL DIAMETER | 1.750 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | -100.00 TO +400.00 ACTUATION POINT DEGREES FAHRENHEIT AND -100.00 TO +400.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| CONTACT STIMULUS RATING | AF75.00 ACTUATION POINT NOMINAL AND AF70.00 DEACTUATION POINT NOMINAL |
| OPERATING TEMP RATING | -100.0 DEG FAHRENHEIT MINIMUM AND 600.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | IMMERSION WELL |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | FLANGE AND THREADED HOLE |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.082 INCHES NOMINAL |
| FEATURES PROVIDED | TAMPER PROOF CAP |