Part Details | PRESSURE SWITCH
5930-00-121-4960 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 150152, 15015-2, M9395102, M9395/1-02, MILS93951, MIL-S-9395/1, 5930-00-121-4960, 00-121-4960, 5930001214960, 001214960
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | NOV 01, 1968 | 00-121-4960 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-121-4960
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 15015-2 | 98505 | HYDRA-ELECTRIC COMPANY |
| M9395/1-02 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-S-9395/1 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-121-4960
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 5.090 INCHES NOMINAL |
| OVERALL HEIGHT | 2.030 INCHES MAXIMUM |
| OVERALL WIDTH | 3.590 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BD700.00 ACTUATION POINT NOMINAL AND BD350.00 DEACTUATION POINT NOMINAL AND BD350.00 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | BRACKET |
| SPECIAL FEATURES | THREE MTG HOLES 0.203 IN. DIA IN LINE SPACED 1/310 IN. C TO C |
| SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |