NSN 5930-00-144-2058

Part Details | PRESSURE SWITCH

5930-00-144-2058 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 6080BN3000PSI, 6080BN3000SI, 6080BN3000-SI, B420B3000PSI, 4691028501, 46910285-01, 46910285, 5930-00-144-2058, 00-144-2058, 5930001442058, 001442058

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 17, 197300-144-205800206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-144-2058
Part Number Cage Code Manufacturer
6080BN3000PSI38056ASHCROFT INC.
6080BN3000-SI38056ASHCROFT INC.
B420B3000PSI38056ASHCROFT INC.
46910285-0180234VAPOR CORPSUB OF BRUNSWICK CORP
4691028580234VAPOR CORPSUB OF BRUNSWICK CORP
Technical Data | NSN 5930-00-144-2058
Characteristic Specifications
STYLE DESIGNATOR5 CYLINDRICAL W/FLANGE
OVERALL LENGTH4.000 INCHES NOMINAL
OVERALL HEIGHT5.750 INCHES NOMINAL
OVERALL WIDTH2.312 INCHES NOMINAL
BODY HEIGHT2.750 INCHES NOMINAL
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE+90.00 TO +3300.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +60.00 TO +3270.00 DEACTUATION POINT POUNDS PER SQUARE INCH
CONTACT ADJUSTMENT TYPE INTERNAL DEACTUATION POINT HEX NUT AND INTERNAL ACTUATION POINT HEX NUT
CONTACT STIMULUS RATINGBB3000.00 ACTUATION POINT NOMINAL AND BB30.00 DIFFERENTIAL POINT NOMINAL
MEDIA FOR WHICH DESIGNED GAS
PROOF PRESSURE12000.00 POUNDS PER SQUARE INCH
TERMINAL TYPE SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.203 INCHES NOMINAL
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS3.250 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.625 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS3.312 INCHES NOMINAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION WATERTIGHT