Part Details | PRESSURE SWITCH
5930-00-170-3920 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: W2619185700, W26191857-00, FR2619185700, FR26-191857-00, 2668397030, 266-8397-030, 2668397030, 266-8397-030, 5930-00-170-3920, 00-170-3920, 5930001703920, 001703920
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | AUG 25, 1972 | 00-170-3920 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL
Cross Reference | NSN 5930-00-170-3920
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| W26191857-00 | 85274 | DWYER INSTRUMENTS INCDBA PROXIMITY CONTROLS |
| FR26-191857-00 | 85274 | DWYER INSTRUMENTS INCDBA PROXIMITY CONTROLS |
| 266-8397-030 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
| 266-8397-030 | 95105 | ROCKWELL COLLINS, INC.DIV GOVERNMENT SYSTEMS - DALLAS |
Technical Data | NSN 5930-00-170-3920
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 6 CYLINDRICAL |
| OVERALL LENGTH | 1.812 INCHES MAXIMUM |
| OVERALL WIDTH | 4.594 INCHES MINIMUM AND 4.656 INCHES MAXIMUM |
| BODY DIAMETER | 3.500 INCHES NOMINAL |
| BODY LENGTH | 1.812 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +1.40 TO +5.00 ACTUATION POINT INCHES OF WATER |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT POINTER |
| OPERATING TEMP RATING | -54.0 DEG CELSIUS MINIMUM AND 55.0 DEG CELSIUS MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 5.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.219 INCHES MINIMUM AND 4.281 INCHES MAXIMUM |