Part Details | THERMOSTATIC SWITCH
5930-00-189-2394 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 2137130G001, 9750328001, 975-0328-001, 5930-00-189-2394, 00-189-2394, 5930001892394, 001892394
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAR 16, 1973 | 00-189-2394 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-189-2394
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2137130G001 | 28527 | HARRIS CORPORATIONDBA ELECTRONIC SYSTEMS, INTEGRATED |
| 975-0328-001 | 97896 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
Technical Data | NSN 5930-00-189-2394
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 3 CYLINDRICAL W/FLANGE |
| OVERALL HEIGHT | 0.902 INCHES MAXIMUM |
| BODY HEIGHT | 0.437 INCHES MAXIMUM |
| OVERALL DIAMETER | 0.600 INCHES MAXIMUM |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AFM36.00 ACTUATION POINT MINIMUM AND AFM50.00 ACTUATION POINT MAXIMUM AND AFM21.00 DEACTUATION POINT MINIMUM AND AFM35.00 DEACTUATION POINT MAXIMUM AND AF15.00 DIFFERENTIAL POINT NOMINAL |
| MEDIA FOR WHICH DESIGNED | GAS |
| TEMP SENSING ELEMENT TYPE | DISC |
| TERMINAL TYPE | TAB, SOLDER LUG |
| MOUNTING METHOD | THREADED STUD |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| TEST DATA DOCUMENT | 96906-MIL-STD-202 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |