Part Details | THERMOSTATIC SWITCH
5930-00-200-9104 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: AR3, 40702010424, 40-702010-424, 40102010114, 40-102010-114, 40102010104, 40-102010-104, 363A814H363, 363A814H36-3, 363A814H363, 363A814H36-3, 5930-00-200-9104, 00-200-9104, 5930002009104, 002009104
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1961 | 00-200-9104 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-00-200-9104
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| AR3 | 65586 | CHROMALOX, INC.DBA OGDEN |
| 40-702010-424 | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
| 40-102010-114 | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
| 40-102010-104 | 73168 | KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS |
| 363A814H36-3 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| 363A814H36-3 | 11660 | WESTINGHOUSE ELECTRIC CORPCONTROL BUSINESS UNIT |
Technical Data | NSN 5930-00-200-9104
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 3 RECTANGULAR |
| OVERALL LENGTH | 6.875 INCHES NOMINAL |
| OVERALL HEIGHT | 10.016 INCHES NOMINAL |
| OVERALL WIDTH | 3.500 INCHES MAXIMUM |
| BODY HEIGHT | 7.875 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +50.00 TO +424.00 ACTUATION POINT DEGREES FAHRENHEIT AND +50.00 TO +300.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| MEDIA FOR WHICH DESIGNED | GAS |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
| BULB LENGTH | 2.687 INCHES NOMINAL |
| BULB DIAMETER | 0.984 INCHES NOMINAL |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION PARALLELOGRAM |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 5.125 INCHES NOMINAL |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.312 INCHES NOMINAL |
| INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.500 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 7.156 INCHES NOMINAL |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
