NSN 5930-00-270-4805

Part Details | PRESSURE SWITCH

5930-00-270-4805 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: 2222378, 22220NB142222378, 222-20NB14-2222378, 5930-00-270-4805, 00-270-4805, 5930002704805, 002704805

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 28, 197300-270-480500206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-270-4805
Part Number Cage Code Manufacturer
222237819278DETROIT SWITCH, INC.
222-20NB14-222237819278DETROIT SWITCH, INC.
Technical Data | NSN 5930-00-270-4805
Characteristic Specifications
STYLE DESIGNATOR0 CYLINDRICAL W/FLANGE
OVERALL LENGTH5.750 INCHES NOMINAL
OVERALL HEIGHT10.812 INCHES NOMINAL
OVERALL WIDTH3.000 INCHES NOMINAL
BODY LENGTH4.875 INCHES NOMINAL
BODY HEIGHT10.312 INCHES NOMINAL
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+250.00 TO +3000.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +210.00 TO +2920.00 DEACTUATION POINT POUNDS PER SQUARE INCH
CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT HEX NUT WITH SCALE AND INTERNAL DEACTUATION POINT HEX NUT WITH SCALE
OPERATING TEMP RATING-30.0 DEG FAHRENHEIT MINIMUM AND 580.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
PROOF PRESSURE3600.00 POUNDS PER SQUARE INCH GAGE
TERMINAL TYPE SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.375 INCHES NOMINAL
MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS3.000 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.500 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS4.250 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT
SPECIAL FEATURESPHOSPHOR BRONZE HOUSING FOR OXYGEN SERVICE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION GENERAL PURPOSE-NEMA TYPE 1
PRECIOUS MATERIAL SILVER
PRECIOUS MATERIAL AND LOCATIONCONTACTS SILVER