Part Details | PRESSURE SWITCH
5930-00-344-1786 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 506107264, 506107-26-4, 506107264, 506107-26-4, 50607264, 50607-26-4, 885C879P1, 885C879P0001, E37C108, E37C-108, 5930-00-344-1786, 00-344-1786, 5930003441786, 003441786
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 15, 1974 | 00-344-1786 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-344-1786
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 506107-26-4 | 08664 | BRISTOL BABCOCK INCINSTRUMENTS-SYSTEMS DIV |
| 506107-26-4 | 1CFF7 | BRISTOL INC.DBA REMOTE AUTOMATION SOLUTIONS DIV |
| 50607-26-4 | 1CFF7 | BRISTOL INC.DBA REMOTE AUTOMATION SOLUTIONS DIV |
| 885C879P1 | 99971 | LOCKHEED MARTIN CORPNAVAL ELECTRONICS & SURVEILLANCE |
| 885C879P0001 | 99971 | LOCKHEED MARTIN CORPNAVAL ELECTRONICS & SURVEILLANCE |
| E37C-108 | 14314 | UNITED ELECTRIC CONTROLS COMPANYDBA PRECISION SENSORS |
Technical Data | NSN 5930-00-344-1786
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 8 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 2.323 INCHES NOMINAL |
| BODY LENGTH | 1.375 INCHES MAXIMUM |
| OVERALL DIAMETER | 1.312 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | ABSOLUTE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BC13.50 ACTUATION POINT NOMINAL AND BC14.50 DEACTUATION POINT NOMINAL AND BC1.00 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 30.00 POUNDS PER SQUARE INCH ABSOLUTE |
| TERMINAL TYPE | WIRE HOOK |
| MOUNTING METHOD | CLAMP |
| SENSING ELEMENT BURST PRESSURE | 75.00 POUNDS PER SQUARE INCH ABSOLUTE |