Part Details | ROTARY SWITCH
5930-00-410-5364 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 42A360414N, 42A36-04-1-4N, 19004A4, 790000329, 7900003-29, M378640378, M3786/4-0378, MILS37864, MIL-S-3786/4, MILDTL37864, MIL-DTL-3786/4, 5930-00-410-5364, 00-410-5364, 5930004105364, 004105364
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | AUG 11, 1969 | 00-410-5364 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT
Cross Reference | NSN 5930-00-410-5364
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 42A36-04-1-4N | 81073 | GRAYHILL, INC |
| 19004A4 | 91812 | JANCO CORPORATIONDBA ESTERLINE MASON |
| 7900003-29 | 90536 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
| M3786/4-0378 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-S-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-DTL-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-410-5364
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
| OVERALL LENGTH | 2.937 INCHES NOMINAL |
| OVERALL DIAMETER | 1.000 INCHES MINIMUM AND 1.306 INCHES MAXIMUM |
| INDIVIDUAL SECTION QUANTITY | 4 |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
| TERMINAL TYPE | TAB, SOLDER LUG |
| TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL--3786 TO 4 GOVERNMENT SPECIFICATION |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| OPERATING TEMP RANGE | -65.0 TO +85.0 DEG CELSIUS |