Part Details | ROTARY SWITCH
5930-00-421-6358 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 44A300415N, 44A30-04-1-5N, 19054C5N, 1905-4C5N, 19054B5, 1905-4B5, M378640070, M3786/4-0070, MILS37864, MIL-S-3786-4, MILDTL37864, MIL-DTL-3786/4, 2599556370, 259-9556-370, 5930-00-421-6358, 00-421-6358, 5930004216358, 004216358
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | DEC 23, 1970 | 00-421-6358 | 02134 ( SWITCH, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
TAP, CIRCULAR, BUSHING MOUNT
Cross Reference | NSN 5930-00-421-6358
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 44A30-04-1-5N | 81073 | GRAYHILL, INC |
| 1905-4C5N | 91812 | JANCO CORPORATIONDBA ESTERLINE MASON |
| 1905-4B5 | 91812 | JANCO CORPORATIONDBA ESTERLINE MASON |
| M3786/4-0070 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-S-3786-4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-DTL-3786/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 259-9556-370 | 13499 | ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS |
Technical Data | NSN 5930-00-421-6358
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
| OVERALL LENGTH | 2.742 INCHES MINIMUM AND 3.132 INCHES MAXIMUM |
| OVERALL DIAMETER | 1.100 INCHES MINIMUM AND 1.306 INCHES MAXIMUM |
| INDIVIDUAL SECTION QUANTITY | 4 |
| SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
| TERMINAL TYPE | TAB, SOLDER LUG |
| TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| OPERATING TEMP RANGE | -65.0 TO +85.0 DEG CELSIUS |