Part Details | THERMOSTATIC SWITCH
5930-00-471-4573 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: HH22PB032, 162930, 1629-30, 5930-00-471-4573, 00-471-4573, 5930004714573, 004714573
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 08, 1971 | 00-471-4573 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-00-471-4573
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| HH22PB032 | 10855 | CARRIER CORPORATION |
| 1629-30 | 65289 | EMERSON ELECTRIC COWHITE RODGERS CO DIV |
Technical Data | NSN 5930-00-471-4573
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 2 RECTANGULAR |
| OVERALL LENGTH | 3.312 INCHES NOMINAL |
| OVERALL HEIGHT | 5.375 INCHES NOMINAL |
| OVERALL WIDTH | 2.500 INCHES NOMINAL |
| BODY LENGTH | 2.312 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +20.00 TO +75.00 ACTUATION POINT DEGREES FAHRENHEIT AND +17.00 TO +72.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| CAPILLARY TUBE LENGTH | 96.0 INCHES NOMINAL |
| BULB LENGTH | 7.250 INCHES NOMINAL |
| BULB DIAMETER | 0.375 INCHES NOMINAL |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | SLOT |
| MOUNTING SLOT WIDTH | 0.375 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.500 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.625 INCHES NOMINAL |