Part Details | LIQUID LEVEL SWITCH
5930-00-557-8834 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.
Alternate Parts: LS239221, LS23922-1, 5930-00-557-8834, 00-557-8834, 5930005578834, 005578834
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | NOV 08, 1974 | 00-557-8834 | 37187 ( SWITCH, LIQUID LEVEL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-557-8834
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| LS23922-1 | 04034 | GEMS SENSORS INC. |
Technical Data | NSN 5930-00-557-8834
| Characteristic | Specifications |
|---|---|
| INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES RESISTIVE LOAD |
| ELECTRICAL CONNECTION TYPE | CABLE |
| POWER CABLE LENGTH | 24.000 INCHES MINIMUM AND 26.000 INCHES MAXIMUM |
| RELAY | NOT INCLUDED |
| LIQUID TYPE FOR WHICH DESIGNED | WATER |
| OPERATING TEMP RATING | 32.0 DEG FAHRENHEIT MINIMUM AND 150.0 DEG FAHRENHEIT MAXIMUM |
| ACTUATION METHOD | BUOYANCY |
| FLOAT QUANTITY | A1$$A1 |
| MOUNTING POSITION | VERTICAL |
| MOUNTING METHOD | THREAD |
| MOUNTING DIMENSIONS | PLUG MTD,1-1/2-12 UNF THD |