Part Details | PRESSURE SWITCH
5930-00-577-0073 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: NA582991, NA5-8299-1, 90099, 90099, 400014, 4000-14, 900001TYPEI, 90000-1TYPEI, 900001, 90000-1, 5930-00-577-0073, 00-577-0073, 5930005770073, 005770073
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-577-0073 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-577-0073
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| NA5-8299-1 | 43999 | BOEING COMPANY, THEDBA BOEING |
| 90099 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| 90099 | 98505 | HYDRA-ELECTRIC COMPANY |
| 4000-14 | 98087 | ITT AEROSPACE CONTROLS LLCDBA ITT AEROSPACE CONTROLS UNIT S |
| 90000-1TYPEI | 81873 | WOODWARD HRT, INC. |
| 90000-1 | 81873 | WOODWARD HRT, INC. |
Technical Data | NSN 5930-00-577-0073
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 3.875 INCHES NOMINAL |
| OVERALL HEIGHT | 3.688 INCHES NOMINAL |
| OVERALL WIDTH | 1.500 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BB1150.00 ACTUATION POINT NOMINAL AND BB650.00 DEACTUATION POINT NOMINAL AND BB500.00 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS |
| PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | BASE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.210 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.125 INCHES NOMINAL |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |