NSN 5930-00-583-1640

Part Details | THERMOSTATIC SWITCH

5930-00-583-1640 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 18050502, 18050-502, 18050501, 18050-501, 18050, 1621242, 5930-00-583-1640, 00-583-1640, 5930005831640, 005831640

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-583-164000451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-583-1640
Part Number Cage Code Manufacturer
18050-50273168KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS
18050-50173168KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS
1805073168KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS
162124210001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
Technical Data | NSN 5930-00-583-1640
Characteristic Specifications
STYLE DESIGNATOR3 CYLINDRICAL W/FLANGE
OVERALL LENGTH4.940 INCHES MAXIMUM
WIDTH ACROSS FLATS1.250 INCHES NOMINAL
BODY DIAMETER0.804 INCHES MINIMUM AND 0.812 INCHES MAXIMUM
BODY LENGTH3.750 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAF35.00 ACTUATION POINT NOMINAL AND AF30.00 DEACTUATION POINT NOMINAL
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD THREADED BUSHING
FEATURES PROVIDED TAMPER PROOF CAP