Part Details | PRESSURE SWITCH
5930-00-621-9953 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M93951002, M9395/10-02, M939510DR1FA, M9395/10-DR1FA, MILS939510, MIL-S-9395/10, MILDTL939510, MIL-DTL-9395/10, 5930-00-621-9953, 00-621-9953, 5930006219953, 006219953
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 27, 1975 | 00-621-9953 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL
Cross Reference | NSN 5930-00-621-9953
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M9395/10-02 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M9395/10-DR1FA | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-S-9395/10 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-DTL-9395/10 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-00-621-9953
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 6 CYLINDRICAL |
| OVERALL LENGTH | 2.870 INCHES MAXIMUM |
| OVERALL WIDTH | 1.939 INCHES NOMINAL |
| BODY DIAMETER | 0.994 INCHES MINIMUM AND 0.996 INCHES MAXIMUM |
| BODY LENGTH | 1.162 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BB150.00 ACTUATION POINT NOMINAL AND BB50.00 DEACTUATION POINT NOMINAL |
| OPERATING TEMP RATING | -53.9 DEG CELSIUS MINIMUM AND 176.6 DEG CELSIUS MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| PROOF PRESSURE | 800.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.521 INCHES MINIMUM AND 1.541 INCHES MAXIMUM |
| TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL--9395 TO 10 GOVERNMENT SPECIFICATION |
| SENSING ELEMENT BURST PRESSURE | 1200.00 POUNDS PER SQUARE INCH |