NSN 5930-00-644-2822

Part Details | PRESSURE SWITCH

5930-00-644-2822 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Alternate Parts: K7006324PT1, 9573, LR21505, LR2-1505, LR2150S, LR2-150S, J6DM0D152, J6DMODEL156, J6DMODEL152, A4130REVB, 5930-00-644-2822, 00-644-2822, 5930006442822, 006442822

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-644-282200206 ( SWITCH, PRESSURE )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-644-2822
Part Number Cage Code Manufacturer
K7006324PT102295GENERAL ELECTRIC COGENERAL PURPOSE CONTROL DEPT
957388234UNITED ELECTRIC CONTROLS COMPANY
LR2-150588234UNITED ELECTRIC CONTROLS COMPANY
LR2-150S88234UNITED ELECTRIC CONTROLS COMPANY
J6DM0D15288234UNITED ELECTRIC CONTROLS COMPANY
J6DMODEL15688234UNITED ELECTRIC CONTROLS COMPANY
J6DMODEL15288234UNITED ELECTRIC CONTROLS COMPANY
A4130REVB88234UNITED ELECTRIC CONTROLS COMPANY
Technical Data | NSN 5930-00-644-2822
Characteristic Specifications
STYLE DESIGNATOR CYLINDRICAL W/FLANGE
OVERALL HEIGHT4.844 INCHES NOMINAL
OVERALL WIDTH2.344 INCHES NOMINAL
BODY LENGTH3.562 INCHES NOMINAL
BODY HEIGHT2.500 INCHES NOMINAL
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE+0.00 TO +50.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.00 TO +50.00 DEACTUATION POINT POUNDS PER SQUARE INCH
CONTACT ADJUSTMENT TYPE INTERNAL DEACTUATION POINT HEX NUT AND INTERNAL ACTUATION POINT HEX NUT
MEDIA FOR WHICH DESIGNEDQ$DADF
PROOF PRESSURE75.00 POUNDS PER SQUARE INCH
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION DIAGONAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS4.219 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS1.875 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT