Part Details | PRESSURE SWITCH
5930-00-669-7703 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 1009470, M1102, 90G7, 651221, 6512-21, 1009470, 9002001, 90020-01, 211C2452, 211C245-2, 102704, 10-2704, 5930-00-669-7703, 00-669-7703, 5930006697703, 006697703
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-669-7703 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL
Cross Reference | NSN 5930-00-669-7703
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 1009470 | 77068 | ALLIED-SIGNAL INCDBA ALLIED-SIGNAL AEROSPACE CO |
| M1102 | 53655 | AVOX SYSTEMS INC. |
| 90G7 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| 6512-21 | 02750 | EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION |
| 1009470 | 59364 | HONEYWELL INTERNATIONAL INC.DBA HONEYWELL |
| 90020-01 | 98505 | HYDRA-ELECTRIC COMPANY |
| 211C245-2 | 98505 | HYDRA-ELECTRIC COMPANY |
| 10-2704 | 81205 | THE BOEING COMPANYDBA BOEING |
Technical Data | NSN 5930-00-669-7703
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 8 CYLINDRICAL |
| OVERALL LENGTH | 4.500 INCHES NOMINAL |
| OVERALL HEIGHT | 1.500 INCHES NOMINAL |
| OVERALL WIDTH | 1.700 INCHES NOMINAL |
| BODY LENGTH | 1.200 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | +700.00 TO +1200.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| CONTACT STIMULUS RATING | BB100.00 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 165.0 DEG FAHRENHEIT MAXIMUM |
| PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | BASE |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.120 INCHES NOMINAL |
| SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |