Part Details | FLOW SWITCH
5930-00-789-4970 A switch which is specifically designed to operate by the influence of a gaseous, liquid, or solid media velocity on its actuator.
Alternate Parts: 2050616351, 205-061-635-1, 250F17, 2050616351, 205-061-635-1, 5930-00-789-4970, 00-789-4970, 5930007894970, 007894970
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-789-4970 | 36841 ( SWITCH, FLOW ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-789-4970
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 205-061-635-1 | 97499 | BELL HELICOPTER TEXTRON INC.DBA BELL HELICOPTER |
| 250F17 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| 205-061-635-1 | 80070 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
Technical Data | NSN 5930-00-789-4970
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 4.250 INCHES MAXIMUM |
| OVERALL DIAMETER | 1.150 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AM0.29 ACTUATION POINT NOMINAL AND AM0.125 DEACTUATION POINT MINIMUM AND AM0.19 DEACTUATION POINT MAXIMUM |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | LINE AND INLET CONNECTION AND OUTLET CONNECTION |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |