Part Details | THERMOSTATIC SWITCH
5930-00-815-2114 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: TP302, 5930-00-815-2114, 00-815-2114, 5930008152114, 008152114
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-815-2114 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-00-815-2114
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| TP302 | 05624 | GE AVIATION SYSTEMS LLCDBA GE AVIATION |
Technical Data | NSN 5930-00-815-2114
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 1 RECTANGULAR |
| OVERALL LENGTH | 6.250 INCHES NOMINAL |
| OVERALL HEIGHT | 2.250 INCHES NOMINAL |
| OVERALL WIDTH | 5.375 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +10.00 TO +90.00 ACTUATION POINT DEGREES FAHRENHEIT AND +10.00 TO +90.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB |
| CONTACT STIMULUS RATING | AF4.00 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -40.0 DEG FAHRENHEIT MINIMUM AND 230.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| CAPILLARY TUBE LENGTH | 72.000 INCHES NOMINAL |
| BULB LENGTH | 7.500 INCHES NOMINAL |
| BULB DIAMETER | 0.750 INCHES NOMINAL |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | BRACKET |
| FEATURES PROVIDED | TUBING END SEAL CONNECTION |