Part Details | THERMOSTATIC SWITCH
5930-00-829-5302 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 26020049, 1788840, 509767, 5-09767, 5930-00-829-5302, 00-829-5302, 5930008295302, 008295302
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1962 | 00-829-5302 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-00-829-5302
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 26020049 | 99167 | HAMILTON SUNDSTRAND CORPORATION |
| 1788840 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
| 5-09767 | 18509 | PSG CONTROLS, INC. |
Technical Data | NSN 5930-00-829-5302
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | RECTANGULAR |
| OVERALL LENGTH | 2.500 INCHES NOMINAL |
| OVERALL HEIGHT | 1.000 INCHES NOMINAL |
| OVERALL WIDTH | 0.775 INCHES NOMINAL |
| BODY LENGTH | 2.500 INCHES NOMINAL |
| BODY WIDTH | 0.775 INCHES NOMINAL |
| BODY HEIGHT | 0.688 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AF117.00 ACTUATION POINT NOMINAL AND AF38.50 DEACTUATION POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | THREADED STUD |
| MOUNTING METHOD | BASE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.149 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.000 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.500 INCHES NOMINAL |