Part Details | FLOW SWITCH
5930-00-832-8361 A switch which is specifically designed to operate by the influence of a gaseous, liquid, or solid media velocity on its actuator.
Alternate Parts: 0E5100B0, E5101B, E51-01B, S950001000REVA, S95-0001-000REVA, S950001000, S95-0001-000, 5930-00-832-8361, 00-832-8361, 5930008328361, 008328361
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAR 21, 1967 | 00-832-8361 | 36841 ( SWITCH, FLOW ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-832-8361
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 0E5100B0 | 01963 | CHERRY ELECTRICAL PRODUCTS CORP |
| E51-01B | 01963 | CHERRY ELECTRICAL PRODUCTS CORP |
| S95-0001-000REVA | 14304 | HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION |
| S95-0001-000 | 14304 | HARRIS CORPORATIONDBA HARRIS RF COMMUNICATION |
Technical Data | NSN 5930-00-832-8361
| Characteristic | Specifications |
|---|---|
| OVERALL HEIGHT | 0.750 INCHES NOMINAL |
| OVERALL WIDTH | 0.625 INCHES NOMINAL |
| BODY LENGTH | 1.219 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AN4.00 ACTUATION POINT NOMINAL AND AN0.50 DEACTUATION POINT NOMINAL |
| OPERATING TEMP RATING | 125.0 DEG CELSIUS MAXIMUM AND -65.0 DEG CELSIUS MINIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TERMINAL TYPE | TAB, SOLDER LUG |
| MOUNTING METHOD | UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.122 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.344 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.938 INCHES NOMINAL |
| FEATURES PROVIDED | AUTOMATIC RESET |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND DUSTPROOF |