Part Details | LIQUID LEVEL SWITCH
5930-00-875-9421 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.
Alternate Parts: 80, 5930-00-875-9421, 00-875-9421, 5930008759421, 008759421
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | NOV 06, 1967 | 00-875-9421 | 37187 ( SWITCH, LIQUID LEVEL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-00-875-9421
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 80 | 39305 | ITT MCDONNELL-MILLER A UNIT OF ITTFLUID HANDLING DIV |
Technical Data | NSN 5930-00-875-9421
| Characteristic | Specifications |
|---|---|
| CURRENT RATING AT MAXIMUM RATED VOLTAGE | 22.2 AMPERES RESISTIVE LOAD |
| MAXIMUM CURRENT RATING | 22.2 AMPERES RESISTIVE LOAD |
| VOLTAGE RATING AT MAXIMUM RATED CURRENT | 230.0 VOLTS |
| CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
| ELECTRICAL CONNECTION TYPE | CABLE |
| RELAY | NOT INCLUDED |
| LIQUID TYPE FOR WHICH DESIGNED | KEROSENE |
| OPERATING TEMP RATING | 190.0 DEG FAHRENHEIT MAXIMUM |
| ACTUATION METHOD | BUOYANCY |
| FLOAT QUANTITY | 1 |
| MOUNTING POSITION | HORIZONTAL |
| MOUNTING METHOD | THREAD |
| MOUNTING DIMENSIONS | MTD IN LINE BY ONE EACH INTERNALLY THREADED 1/2 IN. NPT-14 INLET AND OUTLET CONNECTION |
| OVERALL LENGTH | 9.250 INCHES NOMINAL |
| OVERALL HEIGHT | 4.250 INCHES NOMINAL |
| SPECIFIC EQUIPMENT ACCOMMODATED | OIL STORAGE TANK |