Part Details | THERMOSTATIC SWITCH
5930-00-911-2773 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 837AW11JMC, 837H2A, 837-H2A, 5930-00-911-2773, 00-911-2773, 5930009112773, 009112773
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1960 | 00-911-2773 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-00-911-2773
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 837AW11JMC | 01121 | ROCKWELL AUTOMATION, INC. |
| 837-H2A | 01121 | ROCKWELL AUTOMATION, INC. |
Technical Data | NSN 5930-00-911-2773
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 3 RECTANGULAR |
| OVERALL LENGTH | 2.562 INCHES NOMINAL |
| OVERALL HEIGHT | 5.563 INCHES NOMINAL |
| OVERALL WIDTH | 7.500 INCHES NOMINAL |
| BODY HEIGHT | 4.562 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +90.00 TO +200.00 ACTUATION POINT DEGREES FAHRENHEIT AND +90.00 TO +200.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW |
| OPERATING TEMP RATING | 0.0 DEG CELSIUS MINIMUM AND 66.0 DEG CELSIUS MAXIMUM |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | IMMERSION WELL |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | BASE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.624 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.375 INCHES NOMINAL |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |