Part Details | PRESSURE SWITCH
5930-00-930-3779 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 6607155, 6607-1-55, 123SCEC4331, 123SCEC433-1, 5930-00-930-3779, 00-930-3779, 5930009303779, 009303779
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAY 18, 1966 | 00-930-3779 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-930-3779
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6607-1-55 | 02750 | EATON AEROSPACE LLCDIV FLUID & ELECTRICAL DISTRIBUTION |
| 123SCEC433-1 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MISSION SYSTEMS |
Technical Data | NSN 5930-00-930-3779
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 8 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 3.000 INCHES MAXIMUM |
| BODY LENGTH | 2.036 INCHES NOMINAL |
| OVERALL DIAMETER | 1.375 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BD3.75 ACTUATION POINT NOMINAL AND BD2.40 DEACTUATION POINT MINIMUM AND BD3.10 DEACTUATION POINT MAXIMUM |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS |
| PROOF PRESSURE | 250.00 POUNDS PER SQUARE INCH GAGE |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | INLET CONNECTION AND LINE |
| SENSING ELEMENT BURST PRESSURE | 375.00 POUNDS PER SQUARE INCH GAGE |