Part Details | PRESSURE SWITCH
5930-00-946-4477 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: MEL904861, MEL90486-1, 32811001P6, 3281-1001P6, 836AP11VKC, 836A3A, 836-A3A, A6233, 5930-00-946-4477, 00-946-4477, 5930009464477, 009464477
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAR 21, 1966 | 00-946-4477 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-00-946-4477
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MEL90486-1 | 90598 | ENGINEERED AIR SYSTEMS INC.DBA DRS SUSTAINMENT SYSTEMS |
| 3281-1001P6 | 49956 | RAYTHEON COMPANYDBA RAYTHEON |
| 836AP11VKC | 01121 | ROCKWELL AUTOMATION, INC. |
| 836-A3A | 01121 | ROCKWELL AUTOMATION, INC. |
| A6233 | 08441 | SPX CORPORATIONDBA DIELECTRIC COMMUNICATIONS |
Technical Data | NSN 5930-00-946-4477
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 5 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 3.500 INCHES NOMINAL |
| OVERALL HEIGHT | 5.562 INCHES NOMINAL |
| OVERALL WIDTH | 2.562 INCHES NOMINAL |
| BODY HEIGHT | 4.625 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | +0.00 TO +250.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.00 TO +250.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CONTACT STIMULUS RATING | BB180.00 ACTUATION POINT NOMINAL |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 500.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | TAB W/SCREW |
| MOUNTING METHOD | BASE AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | OBTUSE TRIANGLE |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.625 INCHES NOMINAL |
| INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.375 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.625 INCHES NOMINAL |
| SENSING ELEMENT BURST PRESSURE | 600.00 POUNDS PER SQUARE INCH |