NSN 5930-00-990-7469

Part Details | THERMOSTATIC SWITCH

5930-00-990-7469 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 2670162000, 267-0162-000, M234L150030521, M2SL150030514, M2SL1500305-14, M2SL150030514, M2SL-150-0305-14, 5930-00-990-7469, 00-990-7469, 5930009907469, 009907469

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196200-990-746900451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-990-7469
Part Number Cage Code Manufacturer
267-0162-00013499ROCKWELL COLLINS, INC.DBA GOVERNMENT SYSTEMS
M234L15003052182647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
M2SL1500305-1482647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
M2SL-150-0305-1482647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
Technical Data | NSN 5930-00-990-7469
Characteristic Specifications
STYLE DESIGNATOR4 CYLINDRICAL W/FLANGE
OVERALL LENGTH1.400 INCHES NOMINAL
OVERALL HEIGHT0.300 INCHES NOMINAL
BODY DIAMETER0.660 INCHES MAXIMUM
BODY HEIGHT0.300 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATINGAF154.00 ACTUATION POINT NOMINAL AND AF154.00 DEACTUATION POINT MINIMUM AND AF149.00 DEACTUATION POINT MAXIMUM AND AF5.00 DIFFERENTIAL POINT MINIMUM AND AF9.00 DIFFERENTIAL POINT MAXIMUM
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 270.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET AND SLOT
MOUNTING SLOT WIDTH0.156 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.937 INCHES MINIMUM AND 0.999 INCHES MAXIMUM
FEATURES PROVIDED TAMPER PROOF CAP