Part Details | THERMOSTATIC SWITCH
5930-01-032-0509 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: ID1050A, ID-1050-A, 5600210, 5600-210, WHMR1, SEE600200, SEE600-200, 5930-01-032-0509, 01-032-0509, 5930010320509, 010320509
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | DEC 06, 1976 | 01-032-0509 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-01-032-0509
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| ID-1050-A | 09657 | POTTSTOWN WATER HEATER CO INC |
| 5600-210 | 77857 | ROBERTSHAW CONTROLS CONEW STANTON DIV |
| WHMR1 | 77857 | ROBERTSHAW CONTROLS CONEW STANTON DIV |
| SEE600-200 | 77857 | ROBERTSHAW CONTROLS CONEW STANTON DIV |
Technical Data | NSN 5930-01-032-0509
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 0 RECTANGULAR |
| OVERALL LENGTH | 4.688 INCHES NOMINAL |
| OVERALL HEIGHT | 0.969 INCHES NOMINAL |
| OVERALL WIDTH | 1.625 INCHES NOMINAL |
| BODY LENGTH | 4.688 INCHES NOMINAL |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +120.00 TO +180.00 ACTUATION POINT DEGREES FAHRENHEIT AND +120.00 TO +180.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT DIAL AND EXTERNAL ACTUATION POINT DIAL |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| TERMINAL TYPE | TAB, SOLDER LUG |
| MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.000 INCHES NOMINAL |