Part Details | THERMOSTATIC SWITCH
5930-01-098-0756 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 215422401, 21542-2-40-1, 114491233, 11449123-3, 215422401, 21542-2-40-1, 114491233, 11449123-3, 5930-01-098-0756, 01-098-0756, 5930010980756, 010980756
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 25, 1980 | 01-098-0756 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-01-098-0756
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 21542-2-40-1 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
| 11449123-3 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
| 21542-2-40-1 | 73803 | TEXAS INSTRUMENTS INCMETALLURGICAL MATERIALS DIV |
| 11449123-3 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 5930-01-098-0756
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 3 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 2.595 INCHES MAXIMUM |
| WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
| BODY DIAMETER | 0.665 INCHES MAXIMUM |
| BODY LENGTH | 1.500 INCHES MAXIMUM |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AF238.00 ACTUATION POINT NOMINAL AND AF208.00 DEACTUATION POINT NOMINAL |
| OPERATING TEMP RATING | -50.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| TEMP SENSING ELEMENT TYPE | BULB |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | THREADED BUSHING |
| FEATURES PROVIDED | ELECTRICAL BOX CONNECTOR |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE PROOF |