Part Details | PRESSURE SWITCH
5930-01-111-0707 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: M939527DFA, M9395/27-DFA, MILS939527, MIL-S-9395/27, MILDTL939527, MIL-DTL-9395/27, 5930-01-111-0707, 01-111-0707, 5930011110707, 011110707
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | APR 09, 1981 | 01-111-0707 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-111-0707
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M9395/27-DFA | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-S-9395/27 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-DTL-9395/27 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5930-01-111-0707
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 2.425 INCHES MINIMUM AND 2.950 INCHES MAXIMUM |
| OVERALL DIAMETER | 1.150 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | BB13.50 ACTUATION POINT NOMINAL AND BB16.00 DEACTUATION POINT NOMINAL AND BB2.50 DIFFERENTIAL POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | OUTLET CONNECTION |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| TEST DATA DOCUMENT | 81349-MIL-S-9395 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL--9395 TO 27 GOVERNMENT SPECIFICATION |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| SENSING ELEMENT BURST PRESSURE | 800.00 POUNDS PER SQUARE INCH |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPTIGHT AND WEATHERPROOF |
| END ITEM IDENTIFICATION | AN/MST-T1 81755 |