Part Details | PRESSURE SWITCH
5930-01-147-3875 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 611GCEM2, 846728, 703UAAF60V, 703-UAAF-60V, 5930-01-147-3875, 01-147-3875, 5930011473875, 011473875
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 16, 1983 | 01-147-3875 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-147-3875
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 611GCEM2 | 09049 | CUSTOM CONTROL SENSORS, LLCDBA CUSTOM AVIATION SUPPLY |
| 846728 | 62983 | EATON AEROSPACE LLC |
| 703-UAAF-60V | 24038 | SIGMA-NETICS, INC. |
Technical Data | NSN 5930-01-147-3875
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 4.000 INCHES MAXIMUM |
| BODY DIAMETER | 1.440 INCHES NOMINAL |
| OVERALL DIAMETER | 1.870 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | +13.00 TO +80.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +11.60 TO +72.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT HEX NUT AND EXTERNAL ACTUATION POINT HEX NUT |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| PROOF PRESSURE | 1000.00 POUNDS PER SQUARE INCH |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | INPUT PORT |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE AND ELECTRICAL ACCESS PORT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| END ITEM IDENTIFICATION | 98072-VA-101 |