NSN 5930-01-159-3277

Part Details | THERMOSTATIC SWITCH

5930-01-159-3277 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 100371801, 1003718-01, 100371801, 1003718-01, 837A4AX706, 837-A4AX706, 5930-01-159-3277, 01-159-3277, 5930011593277, 011593277

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 06, 198301-159-327700451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR

Cross Reference | NSN 5930-01-159-3277
Part Number Cage Code Manufacturer
1003718-011PQF4L3 TECHNOLOGIES, INC.DBA LINK SIMULATION & TRAINING
1003718-0136378RAYTHEON TECHNICAL SERVICES COMPANY
837-A4AX70601121ROCKWELL AUTOMATION, INC.
Technical Data | NSN 5930-01-159-3277
Characteristic Specifications
STYLE DESIGNATOR0 RECTANGULAR
OVERALL LENGTH5.250 INCHES NOMINAL
OVERALL HEIGHT3.156 INCHES NOMINAL
OVERALL WIDTH2.562 INCHES NOMINAL
BODY LENGTH4.625 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE+60.00 TO +190.00 ACTUATION POINT DEGREES FAHRENHEIT AND +60.00 TO +190.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW
CONTACT STIMULUS RATINGAF110.00 ACTUATION POINT NOMINAL AND AF90.00 DEACTUATION POINT NOMINAL
MEDIA FOR WHICH DESIGNEDQ$DADF
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH72.0 INCHES NOMINAL
BULB LENGTH8.500 INCHES NOMINAL
BULB DIAMETER0.625 INCHES NOMINAL
TERMINAL TYPE SCREW
MOUNTING METHOD BASE AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.219 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION DIAGONAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS1.625 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS1.375 INCHES NOMINAL
FEATURES PROVIDED ELECTRICAL ACCESS PORT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION GENERAL PURPOSE-NEMA TYPE 1