Part Details | PRESSURE SWITCH
5930-01-175-7989 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 751092, 75109-2, 7223432, 722343-2, 5930-01-175-7989, 01-175-7989, 5930011757989, 011757989
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | APR 05, 1984 | 01-175-7989 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-01-175-7989
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 75109-2 | 98505 | HYDRA-ELECTRIC COMPANY |
| 722343-2 | 05869 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5930-01-175-7989
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 7 RECTANGULAR |
| OVERALL LENGTH | 5.000 INCHES MAXIMUM |
| BODY LENGTH | 3.690 INCHES NOMINAL |
| OVERALL DIAMETER | 6.000 INCHES MAXIMUM |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | DECREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AS2.10 ACTUATION POINT NOMINAL AND AS2.70 DEACTUATION POINT NOMINAL |
| OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS |
| PROOF PRESSURE | 12.00 INCHES PER SECOND |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | INPUT PORT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND VIBRATION RESISTANT |