Part Details | FLOW SWITCH
5930-01-182-8742 A switch which is specifically designed to operate by the influence of a gaseous, liquid, or solid media velocity on its actuator.
Alternate Parts: 41138, VTS, 7137081, 713708-1, 7137081, 713708-1, 7137081, 713708-1, 5930-01-182-8742, 01-182-8742, 5930011828742, 011828742
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUN 30, 1984 | 01-182-8742 | 36841 ( SWITCH, FLOW ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-182-8742
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 41138 | 04034 | GEMS SENSORS INC. |
| VTS | 04034 | GEMS SENSORS INC. |
| 713708-1 | 54X10 | RAYTHEON COMPANYDBA RAYTHEON |
| 713708-1 | 49956 | RAYTHEON COMPANYDBA RAYTHEON |
| 713708-1 | 3B150 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5930-01-182-8742
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 5.350 INCHES MINIMUM AND 5.430 INCHES MAXIMUM |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AM34.00 ACTUATION POINT NOMINAL AND AM42.00 DEACTUATION POINT NOMINAL |
| OPERATING TEMP RATING | 0.0 DEG CELSIUS MINIMUM AND 50.0 DEG CELSIUS MAXIMUM |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| MOUNTING METHOD | INLET CONNECTION AND OUTLET CONNECTION AND LINE |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |