Part Details | THERMOSTATIC SWITCH
5930-01-330-8617 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 22232NH12223453, 222-32NH1-2223453, 58323311, 5832331-1, 5930-01-330-8617, 01-330-8617, 5930013308617, 013308617
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | DEC 09, 1990 | 01-330-8617 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
RECTANGULAR
Cross Reference | NSN 5930-01-330-8617
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 222-32NH1-2223453 | 19278 | DETROIT SWITCH, INC. |
| 5832331-1 | 53711 | NAVAL SEA SYSTEMS COMMAND |
Technical Data | NSN 5930-01-330-8617
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 3 RECTANGULAR |
| OVERALL LENGTH | 5.188 INCHES NOMINAL |
| OVERALL HEIGHT | 10.173 INCHES MINIMUM AND 10.773 INCHES MAXIMUM |
| OVERALL WIDTH | 2.690 INCHES MINIMUM AND 2.930 INCHES MAXIMUM |
| BODY HEIGHT | 2.630 INCHES MINIMUM AND 2.870 INCHES MAXIMUM |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | AF53.00 ACTUATION POINT NOMINAL AND AF48.00 DEACTUATION POINT NOMINAL |
| MEDIA FOR WHICH DESIGNED | Q$DADF |
| TEMP SENSING ELEMENT TYPE | BULB |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.350 INCHES MINIMUM AND 2.470 INCHES MAXIMUM |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.600 INCHES MINIMUM AND 0.720 INCHES MAXIMUM |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.220 INCHES MINIMUM AND 3.340 INCHES MAXIMUM |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |