Part Details | PRESSURE SWITCH
5930-01-485-1051 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Alternate Parts: 97501200101, 975012001-01, 97501200101, 975012001-01, X03382, MPL5020.5INCHH20, MPL-502-0.5-INCH-H20, MPL5020.5INCHH20, MPL-502-0.5-INCH-H20, 5930-01-485-1051, 01-485-1051, 5930014851051, 014851051
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAY 17, 2001 | 01-485-1051 | 00206 ( SWITCH, PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE
Cross Reference | NSN 5930-01-485-1051
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 975012001-01 | 0177B | INDRA SISTEMAS SADBA TECNOLOGIA INFORMATICA AVANZADA, |
| 975012001-01 | 1YVV5 | INDRA SYSTEMS, INC. |
| X03382 | 56756 | MICRO PNEUMATIC LOGIC INC |
| MPL-502-0.5-INCH-H20 | 56756 | MICRO PNEUMATIC LOGIC INC |
| MPL-502-0.5-INCH-H20 | 08CJ1 | SRIVATAVA, VINODDBA CHEMICAL ENVIRONMENTAL |
Technical Data | NSN 5930-01-485-1051
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 2 CYLINDRICAL W/FLANGE |
| OVERALL LENGTH | 1.000 INCHES NOMINAL |
| OVERALL HEIGHT | 1.000 INCHES NOMINAL |
| OVERALL WIDTH | 0.391 INCHES NOMINAL |
| BODY LENGTH | 1.000 INCHES NOMINAL |
| BODY WIDTH | 1.000 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | DIFFERENTIAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| MEDIA FOR WHICH DESIGNED | LIQUID |
| TERMINAL TYPE | TAB, SOLDER LUG |
| MOUNTING METHOD | UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| SPECIAL FEATURES | BODY-GLASS-FILLED POLYESTER GRADE SEO,STANDARD;DIAPHRAGM-POLYURETHANE,FLUOROSILICONE,EPDM,POLYTETRAFLUOROETHYLENE;TERMINALS-BRASS GOLD-PLATED;CONTACTS-PHOSPHOR BRONZE W/GOLD INLAY STANDARD;FIXED MOUNT;PORTS-2 PRESSURE & VACUUM |
| CRITICALITY CODE JUSTIFICATION | AGAV |
| END ITEM IDENTIFICATION | FIXTURE ASSY,HOLDING,INTERFACE DEVICE |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | (INAVY)PRESSURE SENSOR,AIRCRAFT |