Part Details | ELECTRICAL CONNECTOR CABLE CLAMP
5935-00-500-8779 A clamp specifically designed to hold an electrical cable firmly in a connector. Must include provisions for attachment to an electrical connector. Excludes ADAPTER (1), CABLE TO CONNECTOR.
Alternate Parts: M8504949219W, M85049/49-2-19W, MS27506B192, MS27506B19-2, MS27506B191, MS27506B19-1, 5935-00-500-8779, 00-500-8779, 5935005008779, 005008779
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 06, 1974 | 00-500-8779 | 23010 ( CLAMP, CABLE, ELECTRICAL CONNECTOR ) |
REFERENCE DRAWINGS & PICTURES
DOUBLE CLAMPING ACTION W OR W/O BUSHING
Cross Reference | NSN 5935-00-500-8779
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M85049/49-2-19W | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MS27506B19-2 | 96906 | MILITARY STANDARDSPROMULGATED BY MILITARY DEPARTMENTS |
| MS27506B19-1 | 96906 | MILITARY STANDARDSPROMULGATED BY MILITARY DEPARTMENTS |
Technical Data | NSN 5935-00-500-8779
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | DOUBLE CLAMPING ACTION W OR W/O BUSHING |
| BODY DIAMETER | 1.219 INCHES MAXIMUM |
| BODY LENGTH | 1.125 INCHES MAXIMUM |
| BODY HEIGHT | 1.469 INCHES MAXIMUM |
| MATERIAL | ALUMINUM ALLOY |
| SURFACE TREATMENT | CADMIUM AND CHROMATE |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED COUPLING |
| THREAD SERIES DESIGNATOR | UNEF |
| NOMINAL THREAD SIZE | 1.063 INCHES |
| THREAD CLASS | 2B |
| THREAD QUANTITY PER INCH | 18 |
| THREAD DIRECTION | RIGHT-HAND |
| NOMINAL THREAD LENGTH | 0.204 INCHES AND 0.219 INCHES |
| CABLE OPENING QUANTITY | 1 |
| CABLE OPENING DIAMETER | 0.625 INCHES NOMINAL |
| SIZE DESIGNATION | 19 |
| TEST DATA DOCUMENT | 81349-MILC38999 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MILC38999 GOVERNMENT SPECIFICATION |