Part Details | TERMINAL BOARD
5940-00-259-4883 An item consisting of insulating material, which is specifically designed to have fastened thereon, or on which are fastened terminal(s), such as screws, solder lugs, solder studs, solderless connectors, clips, and the like. It is usually used for junctions or terminations of wire or cable assemblies. It does not include items as defined above with parts, such as resistors and capacitors mounted thereon. Do not use if a more specific name exists, such as FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (as modified); CONNECTOR (as modified). Excludes TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; and CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. For items having printed electrical conductor paths, see PRINTED WIRING BOARD.
Alternate Parts: 5200069006, 5200069-006, 601Y6, 601GPY06, 601-GP-Y-06, A25355, A253-55, A25355, A253-55, A25355, A253-55, 5940-00-259-4883, 00-259-4883, 5940002594883, 002594883
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-259-4883 | 00404 ( TERMINAL BOARD ) |
REFERENCE DRAWINGS & PICTURES
BARRIER TYPE

Cross Reference | NSN 5940-00-259-4883
Part Number | Cage Code | Manufacturer |
---|---|---|
5200069-006 | 088A2 | C SYSTEMS LLCDBA CRAIG SYSTEMS |
601Y6 | 83330 | DIALIGHT CORPORATION |
601-GP-Y-06 | 26405 | MARATHON SPECIAL PRODUCTSCORPORATION |
A253-55 | 15280 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV ES DEFENSIVE SYSTEMS DIVISION |
A253-55 | 26916 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV MULTIPLE |
A253-55 | 55631 | SCOMILL INC |
Technical Data | NSN 5940-00-259-4883
Characteristic | Specifications |
---|---|
BODY STYLE | BARRIER TYPE |
BOARD CONSTRUCTION | SOLID CONSTRUCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BOARD OVERALL LENGTH | 3.375 INCHES |
BOARD OVERALL WIDTH | 0.875 INCHES |
BOARD OVERALL HEIGHT | 0.875 INCHES |
BOARD HEIGHT EXCLUDING TERMINALS | 0.500 INCHES |
BASE THICKNESS | 0.312 INCHES |
TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
TERMINAL ROW QUANTITY | 1 |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.438 INCHES |
TERMINAL DESIGN | FEEDTHRU |
FEEDTHRU TERMINAL QUANTITY | 6 SINGLE COMBINATION |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.062 INCHES |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.422 INCHES |
DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.226 INCHES |
DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
MOUNTING HOLE DIAMETER | 0.175 INCHES |