Part Details | ELECTROMAGNETIC RELAY
5945-00-500-7612 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Alternate Parts: 21800C, 21-800C, 001540660, 00154-0660, 07766C, 5945-00-500-7612, 00-500-7612, 5945005007612, 005007612
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 06, 1974 | 00-500-7612 | 32512 ( RELAY, ELECTROMAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-00-500-7612
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 21-800C | 30374 | CONTROLLIX CORPORATIONDBA WALTON HILLS |
| 00154-0660 | 93568 | HARSCO CORPBMY-COMBAT SYSTEMS DIV |
| 07766C | 00701 | LAKE SHORE ELECTRIC CORPORATION |
Technical Data | NSN 5945-00-500-7612
| Characteristic | Specifications |
|---|---|
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 28.0 DC |
| COIL QUANTITY | 3 |
| WINDING QUANTITY | 3 |
| FREQUENCY IN HERTZ | 50.0 MINIMUM AND 60.0 MAXIMUM |
| DUTY TYPE | CONTINUOUS |
| OVERALL LENGTH | 8.750 INCHES NOMINAL |
| OVERALL WIDTH | 6.250 INCHES NOMINAL |
| OVERALL HEIGHT | 3.470 INCHES NOMINAL |
| SPECIAL FEATURES | VOLTAGE SENSING 3 PHASE RELAY |