Part Details | ELECTRICAL SOLENOID
5945-00-602-9006 An item consisting of one or more coils surrounding an iron core. The coil(s) and the core are moveable in relation to each other. The axial or rotary movement is a result of the magnetic flux of the coil. It is designed to convert electrical energy into mechanical energy. It does not include switch contacts. See also RELAY, ELECTROMAGNETIC, and ELECTROMAGNETIC ACTUATOR.
Alternate Parts: M01065, M0-1065, 117902, 11790-2, 117902, 11790-2, 5945-00-602-9006, 00-602-9006, 5945006029006, 006029006
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1963 | 00-602-9006 | 00310 ( SOLENOID, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
L-FRAME
Cross Reference | NSN 5945-00-602-9006
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M0-1065 | 80249 | BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION INC. |
| 11790-2 | 71468 | ITT CORPORATIONDBA I T T CANNON |
| 11790-2 | 07797 | ROCKER SOLENOID COMPANYDBA ROCKER INDUSTRIES |
Technical Data | NSN 5945-00-602-9006
| Characteristic | Specifications |
|---|---|
| BODY STYLE | L-FRAME |
| MAGNETIC COIL QUANTITY | A1$$A1 |
| DUTY TYPE | CONTINUOUS |
| ACTUATOR STROKE TYPE | PUSH |
| POWER TAKEOFF CONNECTION TYPE | SLOTTED-DRILLED |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 BRACKET AND 4 THREADED HOLE |
| TERMINAL LOCATION | END OPPOSITE ACTUATOR |
| TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY DIAMETER | 1.625 INCHES NOMINAL |
| BODY LENGTH | 2.376 INCHES NOMINAL |
| MOUNTING BASE WIDTH | 1.750 INCHES NOMINAL |
| VOLTAGE RATING IN VOLTS | 24.0 DC NOMINAL AND 24.0 DC NOMINAL |
| CURRENT RATING | 500.0 MILLIAMPERES MAXIMUM AND 4.4 AMPERES MAXIMUM |
| LINEAR FORCE DELIVERED | 5.00 POUNDS |
| ENERGIZING STROKE MAXIMUM LENGTH | 0.375 INCHES |
| ACTUATOR DIAMETER | 0.500 INCHES MAXIMUM |
| ACTUATOR LENGTH | 0.656 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL |
| POWER TAKEOFF CONNECTION HOLE DIAMETER | 0.189 INCHES NOMINAL |