Part Details | ROTARY RELAY
5945-00-906-1091 A relay whose contact arm may rotate through 360 degrees but not in one operation. Includes rotary relays which automatically reset. For an item having the dual functions of a switch and a relay assembled together on a common mounting, see RELAY-SWITCH. Excludes SWITCH, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).
Alternate Parts: 11011318, 5945-00-906-1091, 00-906-1091, 5945009061091, 009061091
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 01, 1960 | 00-906-1091 | 03890 ( RELAY, ROTARY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-00-906-1091
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 11011318 | 19200 | US ARMY ARDEC RDECOM |
Technical Data | NSN 5945-00-906-1091
| Characteristic | Specifications |
|---|---|
| STRUCTURAL DESIGN | PILE-UP |
| CONTACT CURRENT TYPE | DC |
| CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 30.0 |
| CONTACT CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES RESISTIVE |
| CONTACT MAXIMUM RATED CURRENT | 2.0 AMPERES RESISTIVE |
| CONTACT VOLTAGE RATING AT MAXIMUM RATED CURRENT | 26.5 |
| DC OPERATING VOLTAGE RATING IN VOLTS | 20.0 MINIMUM AND 30.0 MAXIMUM |
| COIL DC RESISTANCE | 630.0 OHMS MINIMUM AND 913.0 OHMS MAXIMUM |
| COIL TERMINAL QUANTITY | 2 |
| RESET FACILITY FEATURE | NOT PROVIDED |
| OVERALL HEIGHT | 0.560 INCHES NOMINAL |
| OVERALL LENGTH | 1.275 INCHES NOMINAL |
| OVERALL WIDTH | 0.410 INCHES NOMINAL |
| SPECIAL FEATURES | TERMINALS ARE 8 SOLDER HOOKS; HERMETICALLY SEALED CASE PER MIL-R-5757; COIL DATA: MAX PICK-UP VOLTAGE AT 25 DEG. C. IS 10 VOLTS; DIELECTRIC STRENGTH IS 500 VOLTS FROM COIL TO CASE AND ACROSS OPEN CONTACTS; OPERATE TIME: 5 MILLISECONDS AT RATED VOLTAGE AND 25 DEG. C.; RELEASE TIME: 5 MILLISECONDS ATRATED VOLTAGE AND 25 DEG. C.; INSULATION RESISTANCE: COIL TO CASE 100 MEGOHMS MIN.,ALL OTHER POINTS 1000 MEGOHMS MIN.; AMBIENT TEMP. RANGE: -65 TO +165 DEG. F.; 2 HOLES 0.120 IN. DIA. |