Part Details | THERMAL RELAY
5945-00-925-2055 A relay switch which is actuated by the effect of internal heat generated by the current in its energizing circuit. For items actuated by ambient, rather than internal temperature changes, see SWITCH, THERMOSTATIC.
Alternate Parts: GT36992, GT3699-2, 9073021, 5945-00-925-2055, 00-925-2055, 5945009252055, 009252055
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 25, 1966 | 00-925-2055 | 03883 ( RELAY, THERMAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-00-925-2055
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| GT3699-2 | 93929 | SPX CORPORATIONDBA RADIODETECTION |
| 9073021 | 18876 | U S ARMY AVIATION AND MISSILECOMMAND |
Technical Data | NSN 5945-00-925-2055
| Characteristic | Specifications |
|---|---|
| SPECIAL FEATURES | CONTACT DATA,SPST,NORMALLY CLOSED,RDG GROUP 217,ELECTRICAL RATINGS,30.8 VDC MAX,NOT RATED FOR CURRENT AT MAX V,4 AMP MAX NOM CURRENT RATING,NOT RATED FOR V AT MAX RATED CURRENT;HEATER DATA,28 VDC RATING,4 W RATING,NOT RATED FOR CURRENT;TERMINAL DATA,2 HEATER TERMINALS,5 TERMINALS FOR CONTACTS;HERMETICALLY SEALED;METAL ENCLOSURE;NOT RATED FOR AMBIENT OPERATING TEMP RANGE;O/A DIM EXCL TERMINALS,2.735 IN. LG,1.000 IN. W,1.375 IN. H;TWO 0.125 IN. DIA MTG HOLES SPACED 1.125 IN. C TO C |