Part Details | ELECTROMAGNETIC RELAY
5945-01-015-8619 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Alternate Parts: 3SAV1854A2, M390166104L, M39016/6-104L, MILR390166, MILR39016-6, 352250025394, 5945-01-015-8619, 01-015-8619, 5945010158619, 010158619
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JAN 29, 1976 | 01-015-8619 | 32512 ( RELAY, ELECTROMAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-015-8619
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 3SAV1854A2 | 01526 | GENICOM CORP |
| M39016/6-104L | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MILR39016-6 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| 352250025394 | H0203 | THALES NEDERLANDDBA THALES LAND & JOINT SYSTEMS |
Technical Data | NSN 5945-01-015-8619
| Characteristic | Specifications |
|---|---|
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.320 INCHES MAXIMUM |
| OVERALL WIDTH | 0.410 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.600 INCHES MAXIMUM |
| TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016 TO 6 GOVERNMENT SPECIFICATION |