Part Details | HYBRID RELAY
5945-01-034-8282 A self-contained device that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. It consists of a combination of semiconductor and passive circuit devices, which in turn control an integral electro-magnetic relay. Excludes relays which employ diodes, rectifiers or other passive devices to achieve contact protection or coil modification. Excludes RELAY, SOLID STATE.
Alternate Parts: R310AKC5001BA, R310-AKC-5001-BA, 584301, 584301, 584301, 5945-01-034-8282, 01-034-8282, 5945010348282, 010348282
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | FEB 01, 1977 | 01-034-8282 | 31445 ( RELAY, HYBRID ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-034-8282
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| R310-AKC-5001-BA | 58657 | LEACH INTERNATIONAL CORPORATIONDBA ESTERLINE POWER SYSTEMS |
| 584301 | 54X10 | RAYTHEON COMPANYDBA RAYTHEON |
| 584301 | 49956 | RAYTHEON COMPANYDBA RAYTHEON |
| 584301 | 3B150 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 5945-01-034-8282
| Characteristic | Specifications |
|---|---|
| FEATURES PROVIDED | HERMETICALLY SEALED |
| SPECIAL FEATURES | 4PDT;TIME DELAY ON OPERATE;10 AMPS RESISTIVE AT 28 VDC OR 115 VAC,400 HZ,OPERATING VOLTAGE +20 TO +30 VDC,OPERATING CURRENT 150 MA MAX,TIME DELAY 5 SEC,RECYCLE TIME 50 MS MAX;1.531 IN. MAX LG,1.531 IN. MAX W,2.747 IN. MA XH;FOUR 0.138-32 THD MTG STUDS ON 1.197 X 1.197 IN. MTG CTRS |