Part Details | ELECTROMAGNETIC RELAY
5945-01-119-4015 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Alternate Parts: 60966971, 6096697-1, JMSWD12M, JMSWD-12M, M3901621010P, M39016/21-010P, M3901621010M, M39016/21-010M, M3901621004M, M39016/21-004M, M3901616003L, M39016/16-003L, M1LR3901621, M1L-R-39016/21, MILR3901621, MIL-R-39016/21, MILPRF39016E, MIL-PRF-39016E, MILPRF3901621, MIL-PRF-39016/21, C45004001, C45004-001, 732D12, 432DD850, 432DD-850, J432D12WM, J432D-12WM, 432D850, 432DD12, 5945-01-119-4015, 01-119-4015, 5945011194015, 011194015
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | SEP 24, 1981 | 01-119-4015 | 32512 ( RELAY, ELECTROMAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-119-4015
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6096697-1 | 03640 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
| JMSWD-12M | 00062 | MARINE ELECTRIC SYSTEMS, INC.DBA MESYS |
| M39016/21-010P | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M39016/21-010M | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M39016/21-004M | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M39016/16-003L | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| M1L-R-39016/21 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-R-39016/21 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-PRF-39016E | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-PRF-39016/21 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| C45004-001 | 50097 | RADIONICS TECHNOLOGIES INC |
| 732D12 | 15818 | TELCOM SEMICONDUCTOR INC |
| 432DD-850 | 11532 | TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS |
| J432D-12WM | 11532 | TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS |
| 432D850 | 11532 | TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS |
| 432DD12 | 11532 | TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS |
Technical Data | NSN 5945-01-119-4015
| Characteristic | Specifications |
|---|---|
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 0.375 INCHES MAXIMUM |
| OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
| FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
| SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT |
| TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016 TO 21 GOVERNMENT SPECIFICATION |
| CRITICALITY CODE JUSTIFICATION | FEAT |