NSN 5945-01-120-1116

Part Details | ELECTROMAGNETIC RELAY

5945-01-120-1116 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Alternate Parts: M3901612004M, M39016/12-004M, M3901612004L, M39016/12-004L, MILR3901612, MIL-R-39016/12, MILPRF3901612, MIL-PRF-39016/12, M3901612028P, M39016/12-028P, M3901612028L, M39016/12-028L, J42012WM, J420-12WM, J42012WL, J420-12WL, 5945-01-120-1116, 01-120-1116, 5945011201116, 011201116

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 12, 198101-120-111632512 ( RELAY, ELECTROMAGNETIC )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-120-1116
Part Number Cage Code Manufacturer
M39016/12-004M81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
M39016/12-004L81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-R-39016/1281349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
MIL-PRF-39016/1281349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
M39016/12-028P81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
M39016/12-028L81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
J420-12WM11532TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS
J420-12WL11532TELEDYNE REYNOLDS, INC.DBA TELEDYNE RELAYS
Technical Data | NSN 5945-01-120-1116
Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
ARC QUENCHING METHOD AIR
COIL QUANTITY2
WINDING QUANTITY2
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH0.280 INCHES MAXIMUM
OVERALL DIAMETER0.370 INCHES MAXIMUM
FEATURES PROVIDED LATCHING CONTACTS AND POLARIZED
SPECIAL FEATURESFAILURE RATE LEVEL 0.1 PERCENT; ONE COIL TERMINAL COMMON TO OTHER
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-R-39016 TO 12 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATIONFEAT
PURPOSE FOR WHICH DESIGNED GENERAL
CUBIC MEASURE0.030 CUBIC INCHES
FRAGILITY FACTOR MODERATELY RUGGED
STORAGE TYPE GENERAL PURPOSE WAREHOUSE