Part Details | ELECTROMAGNETIC RELAY
5945-01-158-3719 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Alternate Parts: ASC1541961, MILR6106, MIL-R-6106, MILPRF6106, MIL-PRF-6106, MS2740130, MS27401-30, 5945-01-158-3719, 01-158-3719, 5945011583719, 011583719
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | JUL 22, 1983 | 01-158-3719 | 32512 ( RELAY, ELECTROMAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-158-3719
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| ASC1541961 | Z4779 | ASC PTY LTD |
| MIL-R-6106 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-PRF-6106 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MS27401-30 | 96906 | MILITARY STANDARDSPROMULGATED BY MILITARY DEPARTMENTS |
Technical Data | NSN 5945-01-158-3719
| Characteristic | Specifications |
|---|---|
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| FREQUENCY IN HERTZ | 50.0 MINIMUM AND 400.0 MAXIMUM |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| OVERALL LENGTH | 1.718 INCHES MAXIMUM |
| OVERALL WIDTH | 0.525 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.425 INCHES MAXIMUM |
| FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
| TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 96906-MS27401 GOVERNMENT STANDARD |
| PURPOSE FOR WHICH DESIGNED | SPECIFIC |
| CUBIC MEASURE | 1.285 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | METAL |
| PRECIOUS MATERIAL | GOLD |
| PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES GOLD |