Part Details | ELECTROMAGNETIC RELAY
5945-01-180-1324 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Alternate Parts: 3SBH1150A2, 3SBH1150A2, R235A0981, R235A098-1, 5945-01-180-1324, 01-180-1324, 5945011801324, 011801324
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | MAY 24, 1984 | 01-180-1324 | 32512 ( RELAY, ELECTROMAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5945-01-180-1324
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 3SBH1150A2 | 1DUQ5 | COMMUNICATIONS INSTRUMENTS INCDIV OF CII TECHNOLOGIES |
| 3SBH1150A2 | 01526 | GENICOM CORP |
| R235A098-1 | 78711 | TELEPHONICS CORPORATIONDBA COMMUNICATIONS SYSTEMS DIVISION |
Technical Data | NSN 5945-01-180-1324
| Characteristic | Specifications |
|---|---|
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| ENERGIZING ELEMENT POWER RATING | 250.0 MILLIWATTS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| OVERALL LENGTH | 1.062 INCHES MAXIMUM |
| OVERALL WIDTH | 0.610 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.527 INCHES MAXIMUM |